Topical Q3 Characterization: What the FDA Expects
Topical Q3 characterization describes the physicochemical and structural fingerprint of a semisolid drug product. It measures appearance, phase state, particle and droplet sizes, polymorphs, rheology, water activity, pH, and density. When a generic matches the reference on Q1 and Q2, Q3 testing is the main in vitro route to support bioequivalence without clinical trials. Why topical bioequivalence is hard Most topical drug products are ointments, creams, or gels that carry a medicine through the skin for a local or systemic effect. Their excipient composition and manufacturing process are complex, and a small change in either can shift the internal microstructure enough to break agreement with the reference listed drug (RLD).…